Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses

Product Details
Customization: Available
Type: Insulated
Conductor Type: Stranded
Still deciding? Get samples of US$ 10/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
65
Year of Establishment
2012-12-14
  • Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
  • Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
  • Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
  • Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
  • Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
  • Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
Find Similar Products

Basic Info.

Model NO.
S1BC4N8-F
Application
Festoon Applications
Conductor Material
Bare Copper
Sheath Material
CPE
Insulation Material
Epr
Material Shape
Round Wire
Range of Application
Frequency Converter Controlled AC Drive
Certification
ISO9001, CE, RoHS
Brand
Aein
Transport Package
Optional
Specification
Multicore
Trademark
AEIN
Origin
Shanghai
HS Code
8544492100

Product Description

 
Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical StressesRubber-sheathed Cables S1BC4N8-F for Medium Mechanical Stresses
Item S1BC4N8-F 
Conductor
Plain copper
Insulation EPR
Outer Sheath CPE
Nominal Voltage
600/1000V
Test voltage 2400 V
Temperature Range
Ambient temperature for fix installation min. -40 °C
Ambient temp. in fully flex. operation min. -25 °C
Color Orange
Certification CE
Application
TECWATER EMV-FC rubber-sheathed cables S1BC4N8-F are intended for connection of electrical equipment in contaminated water and for medium mechanical stresses, e.g. submersible pumps in sewage disposal and treatment as well as submersible mixer. Especially for frequency converter controlled AC drives and if considerable demands in respect of electromagnetic compatibility (EMC) according to the EMC directive imposes. For an effective shielding both ends of cable must have a good shield contact to ground. Due to the various substances in the contaminated water, the cables may be used only in easily accessible areas that can be inspected (installation depth of approx. 10 m, as normally used in sewage water tanks). These cables are also suitable for use in process water, cooling water, mine surface water, rainwater and combined waste water. They further can be used in groundwater and seawater; less stringent specifications in terms of accessibility and inspection can be imposed (in such cases the cables can be used at depths up to 2000 m).

Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical StressesRubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses
Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses

Rubber-Sheathed Cables S1bc4n8-F for Medium Mechanical StressesRubber-Sheathed Cables S1bc4n8-F for Medium Mechanical StressesRubber-Sheathed Cables S1bc4n8-F for Medium Mechanical StressesRubber-Sheathed Cables S1bc4n8-F for Medium Mechanical StressesRubber-Sheathed Cables S1bc4n8-F for Medium Mechanical StressesRubber-Sheathed Cables S1bc4n8-F for Medium Mechanical Stresses

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier